* Accessible path for people with disabilities outside is understood when

 

A. Width at least 0,90 m

B. follow a simple course and are absolutely level without steps and unevenness. Even altitude differences of 2, 3, 4 and 5cm are enough to make a route inaccessible.

 

C. It does not have large slopes (maximum slope 5%).

 

D. it is absolutely free without obstacles along it. Branches of plants protruding in the path, equipment of any kind (stands, signs, tables, tables, etc.) make the route inaccessible.

 

E. It is absolutely free without obstacles at all its height. Elevated or suspended items must be at a height of more than 2.00 m from the floor.

 

F. it is secure throughout its length, e.g. not to cross with underground parking spaces or loading / unloading areas, etc.

 

G. has a stable floor, of hard continuous material, without bumps, recesses and voids. Gravel, sand, fluffy soil, blocked blocks, wooden corridors with large joints and gaps and other similar materials make a route inaccessible. Asphalt, concrete, well-pressed soil, wooden passages without gaps and joints, are suitable materials.

 

H. there are ramps for anode-descent in / from sidewalks with a width of at least 1.50m and without a "step" at meeting with the carriageway.

 

Th. There is interruption of the islands at the crossings.

 

I. has a blind driver and marking at the end of the crossings.

 

IA. has good lighting.

  

* Accessible inside a building means when

 

A. Width at least 0,90 m. completely free of any obstacles.


B. follow a simple course and are absolutely level without steps and unevenness. Even altitude differences of 2.3, 4 and 5cm are enough to make a route inaccessible.

 

C. It does not have large slopes (maximum slope 5%).

 

 

D. it is absolutely free without obstacles along it. Photocopiers, fire extinguishers, living rooms, consumables etc. make the route inaccessible.

 

 

E. It is absolutely free without obstacles at all its height. Elevated or suspended items must be at a height of more than 2.00 m from the floor.

 

 

F. It has - locally - spaces of 1.50X1.50m for maneuvering the wheelchair

 

 

G. has a solid floor, hard hard material (no carpet), no bumps, recesses and voids.

 

 

H. has good lighting.

 

 

Th. Has a marker embossed - in Braille, where there is also a conventional type marking, placed at a height of 0.90-1.20 m from the floor.